Warsaw Metro Carriages Events Recorder
General Parameters:
- Record errors: below 1 on 106 bits,
- Voltage: 110V DC,
- Power consumption: max 20 VA,
- Normal temperature range: -25 °C ÷ +70 °C,
- Max. temperature range: -35 °C ÷ +85°C,
- Mass (recorder & cassette): about 4500g,
- Mass (cassette): about 800g,
- Recorder dimensions: 320.5 x 57.9 x 193.5 mm.
Parameters controlled by recorder:
- Voltage,
- Correctness of input signal,
- Correctness of cassette records,
- Cassette filled rate and available memory.
Recorder input parameters:
- Input RS485.
This input is used to load data from TIMS system. This input is used also as input for data transmissions from SOP- 2 to next recorder through metro train network.
- Half-duplex transmission,
- 1 start bit,
- 1 parity bit (EVENT PARITY),
- 1 stop bit,
- LSB (Least Significant Bit) transmitted as first,
- Transmissions speed 9600 bits/second.
- Input RxA0
This input is used to load data from Speed Reducing System SOP- 2. This input is used as input for series transmission with opt isolations on transoptor.
- 1 start bit,
- 8 data bits,
- 1 parity bit (ODD PARITY),
- 1 stop bit,
- LSB (Least Significant Bit) transmitted as first,
- Transmission’s speed 9600 bits/second.
- Input PX1 INPUT
Input for pressure converter ATM-PX1. Analogue Input for DC voltage measurement from 0 to 5 V.
Events recorder satisfy a norms:
- Mechanism and connections:
- ARINC No. 404A 15.03.1974 ("AIR TRANSPORT EQUIPMENT CASES AND RACKING),
- Electromagnetic compatibility tests:
- ENV 50121-3-2 emissions according to the table 3 “auxiliary AC or DC power ports”
- ENV 50121-3-2 immunity according to the table 8: “Signal & communication, process measurement & control ports”.
- Vibration and impact tests:
- IEC 571 International Standard